[ATTACH] Also check how you mounted the Z-switch, Should hit the roller, here its already lit up and the screw is pressing on your lever's hinge...
Ahh ok so its its the Plasma Add on! As you were changing settings manually etc in the first post I kinda assumed it was a self-built machine OK...
If you rotate the design 180deg, does the position stay relevative to the drawing, or to the frame? If the inconsistency is in the same spot...
That depends how you mounted the switch. Dr D flo has it like yours. Ours allows more float. Ours rests on the switch while tip is up in the air...
Beta post processor available at GitHub - OpenBuilds/OpenBuilds-MeshCAM-Postprocessor: Post Processor for MeshCAM for use with OpenBuilds Machines...
You got a Z limit error on a Probe. Sounds like you have your Probe switch plugged into your Z Limit input instead of the Probe port? Or your...
What kind of machine did you use as a base? LEAD1010? (Easy option, use the Add-on ) What CAM are you using? If its OpenBuildsCONTROL - check...
Homing sets G53. Your jogging+SetZero (Or XYZ probing) sets Work Coordinates docs:software:openbuilds-control [OpenBuilds Documentation] (Section...
The visible symptoms show the pen moving off the intended path. Something is moving. How's the pen mounted? (Pics of pen mount?)
There are a lot of subtle differences - different motor mounts, different leadscrew system (tension vs compression), different lengths leadscrews...
No i mean as values, we either do $22=0 (OFF) or $22=1 (ON) typically.
It's a Laser CAM. So not really its intended use Well, you get which says it is Which error? But use a Grbl host (CONTROL, UGS, etc - let it...
They will have very high inductance in series - will be incredibly slow. Would say try parallel, and if they are too weak, swop them for motors...
Or get some nice DQ542MA drivers? Much better than DRVs, nice screw terminals all round. Protected in a case with a big heatsink
Also see Tramming: A generic guideline
Aren't you connected over USB cable? (Not sure why you mentioned Wifi) Anything changed recently? Worked on wiring? Anything at all that might...
You need the proper original Grbl
Enter $$=22 for example into the Serial Terminal, grblhal will output the Help for that command [ATTACH] (TIP: Only 1 and 0 is typically used...
Check with the store via Support > New Ticket for a list of official resellers and more info on reseller's versions of core machine designs.
I'd say get the LEAD1515. While a 1010 covers your current needs, you'll soon find work for the larger bed! Modifications are possible, but...