Separate names with a comma.
Some features disabled for guests. Register Today.
Thats correct. Pause in grbl does not hand control back to the user (too risky) Stop, and resume from line only way
Do try flashing again, just to be sure. Then also remember to restart CONTROL so it comes up fresh without the door status checks.
Typing into the DRO and pressing Shift+Enter sets current position to entered value. [ATTACH]
Thanks for the suggestion. Will log enhancement request disable arrows on jog sliders · Issue #353 · OpenBuilds/OpenBuilds-CONTROL
See docs.openbuilds.com/interface
Supposed to be fast. Slow one was probably just failing or waiting for Wifi network not related
Damage to cable between the two or power supply problem where controller isn't providing enough power to Interface.
Should be $44=4 to do Z first then $45=3 (1+2=3 for XY together)
Thats a shame as then the change from 1.25 to 1.333 for Pt isn't the issue..something else is still wrong (90 vs 96dpi). Ok lets leave the Github...
Wonderful! Glad it's resolved
Relay 1 - used to arm/disarm VFD ; or trigger Plasma Inverter (turning on the Tools that needs a dry contact) Is same logical output as Tool...
The resume wizard is not meant for Plasma (as Plasma's need additional probing and zeroing between parts). Best to recam sections that need...
Only if Max Travel is set far incorrectly. It searches up to Max * 1.5 so no thats not the issue here
It doesn't "store" it - as for every toolchange and every job you are supposed to type in how big the endmill / dowel pin you are going to use for...
PSU wasn't wired up with reverse polarity by any chance? noticing you have Black (usual color for negative/gnd) wired to the positive terminal there
Make sure switch is closed (as it would be when door is closed and pushing on it) when the controller boots up
Sorry yeah that's just going to cause trouble :( Plenty cheap blowbacks on Amazon these days [MEDIA] [MEDIA] [MEDIA]
Provide a Grbl Settings backup for review please along with pictures of wiring. Any earlier wiring issues that could have shorted out the 0-10v?...
So seems like it's less an Inkscape changing from 90 to 96dpi issue, but rather CSS changed scaling of Pt to 1.333'px from 1.25px so this bug...
No But try to be more specific. Tell us your issues. Easier than guessing off vague questions (: