Is there a setting to activate this test feature? All tests are green Off status and nothing I do changes the status. For instance the Probe test does not change when the probe touches the endmill but the green lights on the touchplate light up green when contact is made. Just wondering
It is possible if you don't make use of our profiles (which sets things for you to correct values) that you maybe have $10 set to something other than 511?
Point On, that was it. Changed $10 from 0 to $10=511 and now shows Triggered when activated. Thanks for your speedy reply.