Welcome to Our Community

Some features disabled for guests. Register Today.

Basic GRBL command questions.

Discussion in 'General Talk' started by ReneX, Feb 17, 2024.

  1. ReneX

    ReneX New
    Builder

    Joined:
    May 6, 2023
    Messages:
    25
    Likes Received:
    1
    I am in the process of developing a simple user interface to control my custom machine (the machine is powered by a BackBox X32).

    A couple of questions:

    1. What is the command to clear the BlackBox alarm? I am sending "$X" to the BackBox but nothing happens.
    2. Why do jogging commands start with "$J ="? From what I read, I think is a special prefix that allows the system to cancel the command immediately if something goes wrong such as a limit switch alarm is triggered, is that the case?
    3. Is the "$J =" prefix only good for Jogging commands?
    4. What is the significant of commands that start with "$"? Are those GRBL specific commands while commands that start with "G" are G-Code specific commands?.

    Thanks.
     
  2. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,202
    Likes Received:
    4,346
    See Grbl v1.1 Interface and Grbl v1.1 Commands
    Apart the command, do you have the queue management, newlines after commands ("$X\n" for example) etc?

    See Grbl v1.1 Jogging

    See Grbl v1.1 Commands and Grbl v1.1 Configuration
    In essence yes
     
  3. ReneX

    ReneX New
    Builder

    Joined:
    May 6, 2023
    Messages:
    25
    Likes Received:
    1
    Nothing appears to be working, no matter what command I send ($X, $X\n, $X\r\n, you name it). I did noticed that after the limit switch is triggered (the event what raises the alarm) I get the following message:

    [MSG:Reset to continue]

    Does that mean that the only way to get the BlackBox to respond is to do a reset? Is that what you guys do on your Control software? If yes, what commands do you guys send to do the reset and clear the alarm? In other words, what does your "Unlock Alarm" buttons send to the BlackBox to get things working? Usually the Control software shows the commands that are being sent but when it comes to unlocking the alarm, I don't see the commands on the log?

    Thanks.
     
  4. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,202
    Likes Received:
    4,346
  5. ReneX

    ReneX New
    Builder

    Joined:
    May 6, 2023
    Messages:
    25
    Likes Received:
    1
    Thank you,

    I think there is more to this that meet the eye, I have tried sending that command but nothing happens (other alarms clear ok whit that command but it appears that any alarm that follows the [MSG:Reset to continue] will not clear out with that command.

    Just to make sure I am communicating correctly, can you tell me what commands are sent to the BlackBox when I click the "Unlock Alarm" on your Control software (see screenshot below)? If the answer is the same that you gave me before.... do you know why would the reset / alarm not clear out?

    Thanks.


    upload_2024-2-19_19-10-18.png
     
  6. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,202
    Likes Received:
    4,346
    If the firmware specifically requests a Reset, you need to reset, not unlock.
     
  7. ReneX

    ReneX New
    Builder

    Joined:
    May 6, 2023
    Messages:
    25
    Likes Received:
    1
    Do you happen to know what the GRBL reset command is? I tried to look for it but I was not able to find it.

    Thanks.
     
  8. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,202
    Likes Received:
    4,346
    #8 Peter Van Der Walt, Feb 19, 2024
    Last edited: Feb 19, 2024