Welcome to Our Community

Some features disabled for guests. Register Today.

Can't home Z axis

Discussion in 'Control Software' started by apekiller, Mar 14, 2023.

  1. apekiller

    apekiller New
    Builder

    Joined:
    Mar 11, 2023
    Messages:
    2
    Likes Received:
    0
    Hello,
    what can i do to make the "Home All" button also home the Z axis? When I click "Home All" button in OpenBuilds Control or on the Interface, it homes only on X and Y axes. Z stays in place. I have limit switches plugged in and "Limit switches installed" checked.
    The Z axis generally works fine when executing G-code. The problem is when I want to home it.

    BlackBox X32 driver.
     
  2. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,500
    Likes Received:
    4,422
    Make sure your Grbl Settings are correct, $44 and $45 in particular
    Default values does Z first ($44=4) and then XY at the same time ($45=3)
     
  3. Tonyh38

    Tonyh38 New
    Builder

    Joined:
    Mar 3, 2024
    Messages:
    7
    Likes Received:
    0
    I'm having the same issue, it worked before and now it wont home the z axis at all, also im new to this what exactly do I have to type to check to see, every time i type i get an error lol im such a newbie sorry
     
  4. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,500
    Likes Received:
    4,422
    Post a Grbl Settings backup for review (CONTROL > Grbl Settings tab > Backup Settings button)
     
  5. Tonyh38

    Tonyh38 New
    Builder

    Joined:
    Mar 3, 2024
    Messages:
    7
    Likes Received:
    0
     

    Attached Files:

  6. Tonyh38

    Tonyh38 New
    Builder

    Joined:
    Mar 3, 2024
    Messages:
    7
    Likes Received:
    0
    I changed 44 and 45 like you said to do and now it works, but its backwards... im so confused it was working fine and now its all backwards lol
     
  7. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,500
    Likes Received:
    4,422
    You can change those to whatever you need it to be. Z up first is good practice (safety - get tool up and clear of work / hands / clamps / etc before doing an XY move)
    So usually you do $44=4
    And then $45=3 (X and Y at the same time)

    Whats with the number?
    1=X, 2=Y, 4=Z.

    1+2=3 so $45=3 = 2+1 = X+Y
    4 = Z so $44=4 means just Z
     
  8. Tonyh38

    Tonyh38 New
    Builder

    Joined:
    Mar 3, 2024
    Messages:
    7
    Likes Received:
    0
    I will try that and I'll keep you posted thank you.
     
  9. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,500
    Likes Received:
    4,422
    Unless you meant Homing Directions (Thats in $23 Homing Dir)
     