Discussion in 'Controller Boards' started by richard yates, Aug 12, 2021.

  1. richard yates

    Builder

    Joined:
    Apr 27, 2015
    Messages:
    11
    Likes Received:
    1
    I have the Xpro V5 running 4 stepper in an XYYZ configuration. It was working on a previous machine with the same stepper motors. I purchased a workbee and transferred all of the electronics and motors over to it and now I can't get any motion at all.

    I am fairly new to this and could use some troubleshooting advise.

    Also the motors are not getting hot at all and they are not locking up.

    Here is the GRBL settings:
    $0=10
    $1=255
    $2=7
    $3=0
    $4=0
    $5=1
    $6=1
    $10=3
    $11=0.020
    $12=0.002
    $13=0
    $20=0
    $21=1
    $22=1
    $23=1
    $24=1500.000
    $25=1500.000
    $26=25.000
    $27=2.500
    $30=2500.000
    $31=0.000
    $32=0
    $N1=
    $N0=
    $100=201.027
    $101=201.027
    $102=201.027
    $103=200.000
    $104=100.000
    $105=100.000
    $110=1500.000
    $111=1500.000
    $112=1000.000
    $113=1000.000
    $114=1000.000
    $115=1000.000
    $120=150.000
    $121=150.000
    $122=300.000
    $123=200.000
    $124=200.000
    $125=200.000
    $130=800.000
    $131=450.000
    $132=100.000
    $133=300.000
    $134=300.000
    $135=300.000
     
    #1 richard yates, Aug 12, 2021
    Last edited: Aug 12, 2021
  2. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,051
    Likes Received:
    4,313
    Best to contact the vendor you purchased the controller from for tech support. Thanks
     
  3. Giarc

    Giarc OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Jan 24, 2015
    Messages:
    3,016
    Likes Received:
    1,682
    From your vendor:
    Are you using the proper grbl flavor? I assume you are since you just moved everything over, but the V5 xpro is pretty new, so just checking.
     
  4. richard yates

    Builder

    Joined:
    Apr 27, 2015
    Messages:
    11
    Likes Received:
    1
    It is running GRBL 1.3

    Diagnostic shows motors are not getting power
     
  5. Gary Caruso

    Gary Caruso OpenBuilds Volunteer
    Staff Member Moderator Builder

    Joined:
    May 19, 2016
    Messages:
    1,193
    Likes Received:
    532
    4=1

    worked for the v4 at least
     
  6. richard yates

    Builder

    Joined:
    Apr 27, 2015
    Messages:
    11
    Likes Received:
    1
    ok I will try that , thank you
     