Welcome to Our Community

Some features disabled for guests. Register Today.

CNC Xpro v5 motors not turning

Discussion in 'Controller Boards' started by richard yates, Aug 12, 2021.

  1. richard yates

    Builder

    Joined:
    Apr 27, 2015
    Messages:
    11
    Likes Received:
    1
    I have the Xpro V5 running 4 stepper in an XYYZ configuration. It was working on a previous machine with the same stepper motors. I purchased a workbee and transferred all of the electronics and motors over to it and now I can't get any motion at all.

    I am fairly new to this and could use some troubleshooting advise.

    Also the motors are not getting hot at all and they are not locking up.

    Here is the GRBL settings:
    $0=10
    $1=255
    $2=7
    $3=0
    $4=0
    $5=1
    $6=1
    $10=3
    $11=0.020
    $12=0.002
    $13=0
    $20=0
    $21=1
    $22=1
    $23=1
    $24=1500.000
    $25=1500.000
    $26=25.000
    $27=2.500
    $30=2500.000
    $31=0.000
    $32=0
    $N1=
    $N0=
    $100=201.027
    $101=201.027
    $102=201.027
    $103=200.000
    $104=100.000
    $105=100.000
    $110=1500.000
    $111=1500.000
    $112=1000.000
    $113=1000.000
    $114=1000.000
    $115=1000.000
    $120=150.000
    $121=150.000
    $122=300.000
    $123=200.000
    $124=200.000
    $125=200.000
    $130=800.000
    $131=450.000
    $132=100.000
    $133=300.000
    $134=300.000
    $135=300.000
     
    #1 richard yates, Aug 12, 2021
    Last edited: Aug 12, 2021
  2. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,050
    Likes Received:
    4,313
    Best to contact the vendor you purchased the controller from for tech support. Thanks
     
  3. Giarc

    Giarc OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Jan 24, 2015
    Messages:
    3,015
    Likes Received:
    1,680
    From your vendor:
    Are you using the proper grbl flavor? I assume you are since you just moved everything over, but the V5 xpro is pretty new, so just checking.
     
  4. richard yates

    Builder

    Joined:
    Apr 27, 2015
    Messages:
    11
    Likes Received:
    1
    It is running GRBL 1.3

    Diagnostic shows motors are not getting power
     
  5. Gary Caruso

    Gary Caruso OpenBuilds Volunteer
    Staff Member Moderator Builder

    Joined:
    May 19, 2016
    Messages:
    1,193
    Likes Received:
    532
    4=1

    worked for the v4 at least
     
  6. richard yates

    Builder

    Joined:
    Apr 27, 2015
    Messages:
    11
    Likes Received:
    1
    ok I will try that , thank you
     

Share This Page

  1. This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
    By continuing to use this site, you are consenting to our use of cookies.
    Dismiss Notice