    H100 Blackbox setop.jpg

    (NOTE: This applies to the BlackBox X4 only)

    And finally I got my H100 VFD 220V with 1.5Kw Spindel 2 poles air cooled connected to the BlackBox. Follow the instruction above. and the how to configure the H100 VFD below. I have testet it with my CNC and openbuild controle. Dont forget to calibrate the 0 to 10V

    H100 VFD 220V with 1.5Kw Spindel 2 SETUP
    F000 = 0 (Disable parameter lock)
    F001 = 1 (External signal)
    F002 = 1 (Analog input A1)
    F005 = 400 (Frequency limit)
    F004 = 400 (Spindle rated Frequency)
    F003 = 400 (Frequency at 10V will be 400hz)
    F014 = 10 (Acceleration time)
    F015 = 10 (De acceleration time)
    F143 = 02 (number of poles the 1.5kw spindle has)
    F144 = 24.00 (Maximum rotation/minuet)
     
    H@wk, Justin3968, sharmstr and 2 others like this.
  2. Mark Carew

    Mark Carew OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Jun 28, 2013
    Messages:
    2,758
    Likes Received:
    2,441
    Thanks for sharing this info Søren :thumbsup:
     
    Søren Weitling likes this.
  3. H@wk

    H@wk New
    Builder

    Joined:
    Oct 31, 2018
    Messages:
    13
    Likes Received:
    14
    Worked well. Thanks
     
    Søren Weitling likes this.
  4. Nativeman30

    Builder

    Joined:
    Nov 25, 2022
    Messages:
    1
    Likes Received:
    2
    Awesome. A slight modification if you have the X32 is run the enable line from the tool connector to X1 and the 0-10 from the 0-10V connector.
     
    Midark2016 and Søren Weitling like this.
  5. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,051
    Likes Received:
    4,313
    Just make very sure that the X1 does NOT have a 24v pullup (Some VFDs do) or it may damage the BlackBox.
     
  6. goldentuna

    Builder

    Joined:
    Aug 26, 2016
    Messages:
    9
    Likes Received:
    1
    Can I assume this is still the same hook up configuration for the same model in the 110v 1.5kw spindle?
     
  7. Søren Weitling

    Søren Weitling Well-Known
    Builder

    Joined:
    Dec 13, 2019
    Messages:
    30
    Likes Received:
    25
    Yes should be no difference.
     
    goldentuna likes this.
  8. Ksheren

    Ksheren New
    Builder

    Joined:
    Sep 11, 2017
    Messages:
    13
    Likes Received:
    1
    I want to just turn the VFD on and off only. What plugs do I use on my X32 and what terminals on the VFD
    (H100 110 volt).

    Thanks in advance, (newbie)

    Kevin

    vfd-h100.png
     
  9. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,051
    Likes Received:
    4,313
  10. Ksheren

    Ksheren New
    Builder

    Joined:
    Sep 11, 2017
    Messages:
    13
    Likes Received:
    1
    I have attempted to adjust the voltage. Is the above link says to do and the most I can get is.03 volts dc.

    Very frustrated any help would be appreciated.

    Thanks in advance,
    Kevin IMG_4339.jpg IMG_4341.jpg IMG_4340.jpg
     
  11. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,051
    Likes Received:
    4,313
    Any earlier wiring different from the picture you sent? History along the way could have an impact

    Also post a Grbl Settings backup
     
  12. Ksheren

    Ksheren New
    Builder

    Joined:
    Sep 11, 2017
    Messages:
    13
    Likes Received:
    1
    This is a new build. It is the only way hooked up. Do I need it hooked to the program to be able to check it?
     
  13. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,051
    Likes Received:
    4,313
  14. Nitrotoker

    Builder

    Joined:
    Apr 19, 2022
    Messages:
    2
    Likes Received:
    1
    Do you think the 2.2kw spindle is 2 poles also? I can't find any info on that. Thanks for sharing!!
     
  15. Søren Weitling

    Søren Weitling Well-Known
    Builder

    Joined:
    Dec 13, 2019
    Messages:
    30
    Likes Received:
    25
    Hello I dont have a 2.2KW, but maybe it works.
     
  16. Nitrotoker

    Builder

    Joined:
    Apr 19, 2022
    Messages:
    2
    Likes Received:
    1
    I does work, Thank you
     
    Søren Weitling likes this.
  17. Søren Weitling

    Søren Weitling Well-Known
    Builder

    Joined:
    Dec 13, 2019
    Messages:
    30
    Likes Received:
    25
    Perfect :)
     
  18. Mohamma393

    Builder

    Joined:
    Oct 18, 2022
    Messages:
    73
    Likes Received:
    5
    How to check it
    I have same vfd but would like to check
     
  19. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,051
    Likes Received:
    4,313
    Multimeter on the VFD terminals you want to use, before hooking them up to BlackBox
     
  20. Mohamma393

    Builder

    Joined:
    Oct 18, 2022
    Messages:
    73
    Likes Received:
    5
  21. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,051
    Likes Received:
    4,313
    We provide the standard 0-10v signal. Everything else is VFD manual / VFD vendor side - i.e how to configure your 3rd party VFD to accept an industry standard 0-10v control signal. Speak to your VFD vendor.
    All VFDs we've come across could be setup to run just fine with just the GND/0-10v Signal. Enable etc not even needed if setup of VFD parameters is done right
     
  22. Mohamma393

    Builder

    Joined:
    Oct 18, 2022
    Messages:
    73
    Likes Received:
    5
    When i connect enable from BB32 to x1 vfd
    0-10v to Vi1 vfd
    Gnd to gnd vfd
    Spindle spinning all the time even if Bb off and usb disconnected

    then connected gnd vfd to x1 vfd
    0-10v bb to VI1 vfd
    Same result

    then used NO relay from my old blackbox to X1 and COM relay to gnd incthe vfd and that works to control vfd run/off mode
    I think if i use 0-10v will go back to same result can’t stop spindle , for me no problem to adjustment Hz via vfd potentiometer

    The question is
    Is there something to worry about if used NO in the new blackbox32 ?


    And yes im in contact with vfd seller just need to wait 24h for every single massage
     
  23. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,051
    Likes Received:
    4,313
    You forgot to setup MinFreq in VFD parameters
     
  24. Mohamma393

    Builder

    Joined:
    Oct 18, 2022
    Messages:
    73
    Likes Received:
    5
    I set minimum operation to 80hz to to avoid very low speed

    0-10v analog is work correctly
    But run commands is the problem
     
  25. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,051
    Likes Received:
    4,313
    A properly setup VFD just needs 0-10 signal. Stops when commanded to go below 120hz (7200 RPM min for air cooling to work properly).
     
  26. Mohamma393

    Builder

    Joined:
    Oct 18, 2022
    Messages:
    73
    Likes Received:
    5
    What I understood is 0-10v to control control hz
    And x1&2&3&4&5&6 to run/stop spindle

    0-10v works fine
    Run command whenever it has gnd and something else, spindle running in minimum frequency without stop
    Even if BB is off and usb disconnected

    NO relay in BB is working good to run /stop
    OB to X1 comm to vfd gnd

    I didn’t try but i think if connect 0-10v and gnd from blackbox to vfd gnd
    then will have full circuit + and gnd will go back to same result

    now it’s fine to control on off spindles
    Rpm in the vfd keyboard
     
    #26 Mohamma393, Nov 2, 2023
    Last edited: Nov 2, 2023
  27. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,051
    Likes Received:
    4,313
    Can use it. But something in VFD setup could still improve because its not needed what set up correctly
     
  28. Mohamma393

    Builder

    Joined:
    Oct 18, 2022
    Messages:
    73
    Likes Received:
    5
    Yes im sure you are right
    Just waiting to finish the very slow discussion with the Chinese

    thank you so much
     
  29. rmorrow50

    rmorrow50 New
    Builder

    Joined:
    Nov 26, 2023
    Messages:
    4
    Likes Received:
    1
    Good afternoon all. I have a question. I just installed a VFD and spindle I have a BlackBox X32 I hooked up the 0-10V and Tool connections and it works but no matter what bit I select in VCarve the spindle always goes to 100% or 10V even when the speed on the bit is 1000 RPM, what am I missing do I need to change something in VCarve?
     
  30. Alex Chambers

    Alex Chambers Master
    Moderator Builder

    Joined:
    Nov 1, 2018
    Messages:
    2,785
    Likes Received:
    1,366

Share This Page

  1. This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
    By continuing to use this site, you are consenting to our use of cookies.
    Dismiss Notice