Welcome to Our Community

Some features disabled for guests. Register Today.

Stepper Overheat

Discussion in 'Motors' started by Benjamin Vg, Sep 14, 2023.

  1. Benjamin Vg

    Benjamin Vg Well-Known
    Builder

    Joined:
    Jan 13, 2016
    Messages:
    136
    Likes Received:
    10
    Hello,

    I a a noob in electronic and for my project I have plug my stepper with my DM542T like this:
    upload_2023-9-14_19-54-48.png

    My powersupply 48V, 10A is this one Amazon.de and my stepper datasheet is this one: https://ooznest.co.uk/wp-content/uploads/2018/07/NEMA23-Stepper-Motor-175-280.jpg.

    I have followed the advices to takes one that allow me to have 10A to have more torque.
    But when I use it for like 10 minutes, I can hardly touch it because it gets so hot.

    What could I do to avoid it?

    Regards,

    Benjamin
     
  2. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,051
    Likes Received:
    4,313
    That's a 2.8A Peak motor. Running setting would be around 1.8-2A. Use DIP switches on driver and table on top cover - set it to 2A. Or even lower

    Peak = the DO NOT EXCEED value (not the recommended value) - not sure of your frame of reference, but if it was a Car engine, the 2.8A is the RPM Redline. Say 6500RPM. But you'll cruise along most efficiently and without damage around 3000RPM for example.
     
  3. Benjamin Vg

    Benjamin Vg Well-Known
    Builder

    Joined:
    Jan 13, 2016
    Messages:
    136
    Likes Received:
    10
    The DM5402T datasheet is here: https://www.omc-stepperonline.com/download/DM542T.pdf
    So if I refer to this table I should use the third line with Peak Current To 1.91A that is what you mean?
    upload_2023-9-14_20-14-26.png

    For the next time does it make sense for me to use such a powerfull power supply who is able to deliver 10A then?
     
  4. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,051
    Likes Received:
    4,313
    1.9's a good start yeah. If you need a little more torque - 2.37. Can go a little higher - but comission it as needed, don't set it higher than you need. If you can't stall the machine in normal use its more than fine.
     
    Benjamin Vg likes this.
  5. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,051
    Likes Received:
    4,313
    It gets even more complicated :) than just amps in = amps out

    Stepper drivers convert voltages and creates sine waves! They do a lot of work
    Stepper Motors are constant current devices. The driver modifies the output continually to keep the current to the setpoint.

    Simplied:

    Ohms Law says V=I*R

    For example a 3A motor (max rating, not recommended) with 3v coil rating (like ours). Needs 9w per coil * 2 coils =18w per motor max needed
    at 48v thats only going to draw 0,375A from the PSU.
    And thats only when the motor is stopped and holding position. Only time both coils are on. During moves it phases between the coils

    If you need advice, come to us next time (;
     
    Benjamin Vg likes this.
  6. Benjamin Vg

    Benjamin Vg Well-Known
    Builder

    Joined:
    Jan 13, 2016
    Messages:
    136
    Likes Received:
    10
    Thank you very much for you time and advices !
     
    Peter Van Der Walt likes this.

Share This Page

  1. This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
    By continuing to use this site, you are consenting to our use of cookies.
    Dismiss Notice