Discussion in 'Control Software' started by Steve Caldwell, Dec 7, 2023.

  1. Steve Caldwell

    Builder

    Joined:
    Mar 28, 2022
    Messages:
    9
    Likes Received:
    0
    I've got a
    [14:18:32] [ [external from hardware] ] OpenBuilds CONTROL received a FEEDHOLD notification from Grbl: This could be due to someone pressing the HOLD button (if connected)"
    problem. Probe stops at touch point. Not sure what's causing the issue but it gives me no options to get out except abort.
     
  2. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,523
    Likes Received:
    4,424
    Anything wired up to the Feedhold (Door) input?
     
  3. Steve Caldwell

    Builder

    Joined:
    Mar 28, 2022
    Messages:
    9
    Likes Received:
    0
    No door on the unit
     
  4. Steve Caldwell

    Builder

    Joined:
    Mar 28, 2022
    Messages:
    9
    Likes Received:
    0
    In the troubleshooting mode it has, under buttons: Off, Hold/Door, Off
     
  5. Steve Caldwell

    Builder

    Joined:
    Mar 28, 2022
    Messages:
    9
    Likes Received:
    0
    Hold door is in Red
     
  6. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,523
    Likes Received:
    4,424
    Yes, but do you have anything wired to the DOOR port? An estop, or similar would count too. Anything wired?


    Or perhaps nonstandard Grbl Settings? Post a backup for review
     
  7. Steve Caldwell

    Builder

    Joined:
    Mar 28, 2022
    Messages:
    9
    Likes Received:
    0
    Yeah I do have an E-Stop, settings reversed?
     
  8. Steve Caldwell

    Builder

    Joined:
    Mar 28, 2022
    Messages:
    9
    Likes Received:
    0
    It started acting up bout the time I put it in.
     
  9. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,523
    Likes Received:
    4,424
    Either wired wrong, configured wrong, or EMI.

    More importantly the Door input is for a Door switch.

    E-stops shouldn't be connected there. E-Stops should cut Power. Wall socket > E stop > Power strip > all machine accessories.
     
    David the swarfer likes this.
  10. Steve Caldwell

    Builder

    Joined:
    Mar 28, 2022
    Messages:
    9
    Likes Received:
    0
    I'll look but was pretty sure it was connected to the e-stop.
    Thanks, got to dig a little deeper
     