Welcome to Our Community

Some features disabled for guests. Register Today.

g-code words consist of a letter and a value. Letter was not found.

Discussion in 'General Talk' started by Tonyh38, Mar 3, 2024.

  1. Tonyh38

    Tonyh38 New
    Builder

    Joined:
    Mar 3, 2024
    Messages:
    7
    Likes Received:
    0
    I keep on this message in Openbuilds Controller, Can someone help me with this, Im kind of new to this, I just need to know what I need to do to correct this issue.
     
  2. Misterg

    Misterg Veteran
    Staff Member Moderator Builder Resident Builder

    Joined:
    Aug 27, 2022
    Messages:
    407
    Likes Received:
    323
    Sounds like an error in your gcode file - can you attach the console output of the error and the gcode file?
     
  3. Giarc

    Giarc OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Jan 24, 2015
    Messages:
    3,039
    Likes Received:
    1,701
    What software and post processor were you using to create the gcode? It needs to be grbl compatible. Home
     
  4. Tonyh38

    Tonyh38 New
    Builder

    Joined:
    Mar 3, 2024
    Messages:
    7
    Likes Received:
    0
    Yea I had the wrong gcode file when I went to save it. Thanks
     
  5. Tonyh38

    Tonyh38 New
    Builder

    Joined:
    Mar 3, 2024
    Messages:
    7
    Likes Received:
    0
    . Vcarve my mistake wrong save, but thanks anyway
     
  6. Giarc

    Giarc OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Jan 24, 2015
    Messages:
    3,039
    Likes Received:
    1,701
    Alex Chambers likes this.
  7. Tommy1

    Tommy1 New
    Builder

    Joined:
    Dec 31, 2024
    Messages:
    3
    Likes Received:
    0
    Hi All,

    I'm new around here, I hope you can help as I am getting the same issue using Openbuilds CAM and Openbuilds Control with a FoxAlien 4040-XE mill:

    A error: 20 - Unsupported or invalid G-code command found in block. [ G1 F1000 X203.5308 Y95.5885 Z-1.0000 S1000 ]

    and

    A error: 2 - Missing the expected G-code word value or numeric value format is not valid. [ G1 F1000 X194.4432 786.7819 Z-1.0000 $1000 ]

    I attach the G-code file, your help identifying the issue would be greatly appreciated.

    Thank you.
     

    Attached Files:

  8. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,497
    Likes Received:
    4,421
  9. Tommy1

    Tommy1 New
    Builder

    Joined:
    Dec 31, 2024
    Messages:
    3
    Likes Received:
    0
    Thanks for the speedy response Peter, I have looked through the EMI documentation and whilst I do have a variable speed spindle motor in my setup, it was not active during the test milling operation and I have since disconnected the cable from the back of the controller in case the cable was still causing a signal issue with the same result.

    I have also tried creating a simple circle in OBCAM and then trying that again (with motor disconnected) and get the same sporadic results. I attach a screenshot of the serial console, it doesn't look to be corrupted, be temporarily disconnected or having missing characters and no hard limit had been hit.

    Could it be something to do with the Grbl settings for this machine expecting to see values in a different format?

    any further help appreciated, Cheers
     

    Attached Files:

  10. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,497
    Likes Received:
    4,421
    What controller are you using? BlackBox X32, BlackBox 4X?
     
  11. Tommy1

    Tommy1 New
    Builder

    Joined:
    Dec 31, 2024
    Messages:
    3
    Likes Received:
    0
    Again, thanks Peter, I have now managed to resolve the issue! Wahooo!

    There was a setting in the controller to prioritise PC communication, as soon as I changed that setting, and assuming the PC stays awake the operation is flawless!

    Thanks again for your help and support!
     
  12. Peter Van Der Walt

    Peter Van Der Walt OpenBuilds Team
    Staff Member Moderator Builder Resident Builder

    Joined:
    Mar 1, 2017
    Messages:
    15,497
    Likes Received:
    4,421

Share This Page

  1. This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
    By continuing to use this site, you are consenting to our use of cookies.
    Dismiss Notice