Separate names with a comma.
Some features disabled for guests. Register Today.
Either incorrect Grbl Settings ($5=7 for BlackBox X32 with our switches on all axes) or the red ones are wired wrong
Essentially yes, but 3.3v (TTL was mainly 5v back in the day) - but same, just a logic signal "tool plug" = TOOL ENABLE yes...
No, its logic signals. Not 12v! 0v for off, 3.3v 10mA for on. Tool Enable = 0/3.3v binary on/off (used to arm a tool) PWM = 03.3v variable duty...
Yes you can use an isolated relay, or a motor controller that matches your gear motors requirements. We provide standard logic signals (enable,...
Use Troubleshooting tab to test switches by hand. Make sure they are not inverted (triggered when off), and correct axis (didn't plug Z into X)
Relay is for signalling (VFD enable / fwd / rev, and Plasma Enable etc). Not meant for powering loads
It tells you that you've disabled the DROs manually. Go back to Troubleshooting tab > Application Diagnostics and untick the DROs you disabled...
We have logic signals for driving a IoT relay docs:blackbox-x32:connect-dewalt-iotrelay [OpenBuilds Documentation], or a VFD spindle Gear motor:...
Oh yes please, not worth risking BlackBox on anything less (: - using different PSU can void warranty
If you are using our profiles, the defaults we provide for our machines are well balanced (performing well, but still reliable). Whenever you plan...
See section 15 of Terms of Service and Rules | OpenBuilds thanks
Use the Stop or Abort buttons.
1) enter valid wifi details in the wizard 2) make sure the network is solid (good signal, working DHCP, is 2.4ghz 802.11b/g compatible) Timeout...
1) check Grubscrews on shaft couplers (could be slipping of shaft coupler) 2) check leadscrews, binding could cause stalls (apply dry/PTFE...
If irs been successfully uninstalled it will be gone. Try again
Sweet then a BlackBox Motion Control System X32 would make a great upgrade to treat yourself to
Double check the VFD parameters, or wire up you FWD/REV/Enable relays to BlackBox X32 On the VFD there should be a min freq config that keeps vfd...
Specifics are important there a couple that "mean the sample thing" but the minor details still have very different resolutions... Would have...
3mm (1/8 inch) - metric No such error known, so post screenshot of the actual error, maybe have Soft Limits on by mistake in Grbl Settings?