Correct, just one gotcha I forgot to mention: on the Coolant output is just to use the negative leg (its a low-side switching mosfet circuit...
800 steps = 2mm pitch (our leadscrews are faster, 8mm pitch (200 steps) for example) On the other hand, they say its a "32bit" microcontroller,...
grblHAL on a BlackBox X32 has a higher step rate (different from Max Rate) so will help, but theres a mechanical design issue at play: That...
No its configurable Grbl v1.1 Configuration But you will reach a ceiling of the stepper drivers, motors, linear components top speed - whereafter...
Grbl v1.1 Configuration > but keep in mind stock profiles are conservatively tuned (room to tune exists) but don't expect to double speeds for...
Thats exactly the solution proposed above yet. Using the DPDT switch. Same concept as you did for router/laser, but applied on the coolant output....
Grbl has ONE tool output. Thus no "signals" for multiple tools. Toggle tool signal between IOT and Laser with one leg of the switch Toggle...
The bearings really only need to constrain the leadscrew axially (along its length) - the diameter of the leadscrew is smaller than the ID of the...
Negative
Use a double pole switch in place of existing one (double pole, double throw) = just one lever, switch both circuits - easier to not forget one
Sounds like one of the 4 wires has a break docs:blackbox-x32:faq-identify-motor-coils [OpenBuilds Documentation]
Seems like the Specialized one would be the upgrade, original owner probably bought it 2nd. But best to direct these questions at Optlaser...
Correct docs:blackbox-x32:layout [OpenBuilds Documentation]
Engraving Laser Head - High Power CNC Laser | Opt Lasers Specialized Engraving Laser - High Power Density Laser | Opt Lasers Both 6W, one just...
By testing. Jog and see... Can do it before connecting motors to the leadscrews
docs:software:lightburn [OpenBuilds Documentation] Port number is not controlled by CONTROL. You OS aasigns port numbers, just use the correct one
Thats quite old, sure you have a Grbl 1.1f or later based controller?
Try 5000 as a test too. 1khz should be good, but try 5000 as well Double check CAM workflow does add S1000 for 100% job to gcode file. Focussed...
Not related to CONTROL update (if in doubt, review OpenBuilds-CONTROL/CHANGELOG.txt at master ยท OpenBuilds/OpenBuilds-CONTROL ) But to show...
Supposed to be 1000 for most CAMs (Ours, LightBURN etc) Maybe other settings wrong too. Post a Grbl Settings backup for review