Inductives don't work so well in parallel. For autosquare we'd recommend Xtension Limit Switch Kit That does look like a firmware bug, so might...
Thats just one suggestion, read the full article and apply all the tips Or disable Hard Limits (Use Soft Limits instead) - but then the still...
Almost unlikely - never had a need for it, just extra expense. What we have is reliable to the point extra expense makes no sense.
Contact your spindle supplier for tech support, or lookup the error code in your VFDs manual. OC = Over Current - so could be incorrect parameters...
Max rate Grbl v1.1 Configuration and Acceleration Grbl v1.1 Configuration set too high
1) During the crash something may have become moved, bent or damaged: Perform a check on all the mechanicals making sure its all perfect, machine...
You mention rewiring. But we mentioned adjusting current down? Is covered in docs:blackbox-x32:currentadjustment [OpenBuilds Documentation] =...
Use easel to generate gcode: https://inventables.zendesk.com/hc/en-us/articles/4406926040979-Exporting-Gcode-From-Easel Then run it as normal...
Have a read through it. You have to set the current
See docs:blackbox-x32:faq-identify-motor-coils [OpenBuilds Documentation] Note your symptoms in the list of section (1) One of the 4 wires not...
In terms of Grbl Settings did you load a backup, fresh machine profile from the dropdown menu, or settings manually (ideally use clean profile in...
That is indicative of a short circuit in wiring. Review all wiring and report back on what you find. A V+ to GND short can cause brownout that...
Same, false limit trigger, likely EMI, see above
Ahh X32, yes 511 and disabled is correct I am not sure, experiment on the serial terminal and see what the DRO tells you. Might have to send...
Awesome stuff, great to have you back in action.
and 24 * 25.4 = 609.6mm? [ATTACH] Not 690? If your max travel is 609.6mm wheres the 762 then? Is it regarding the fact the stopper can't reach...
Newer versions of CONTROL needs Windows 10 yes But in terms of "recognising" as in USB Enumaration, make sure you have the drivers...
24V only please - Use our recommended Meanwell - using a random 36V PSU, or some cheap 24v "LED PSU" that lacks filtering and causes surges WILL...
No, our stepper drives are not able to provide that functionality (takes up too many pins) If the driver isn't going into fault, it would not...
Easiest: see the Documentation : docs:software:overview [OpenBuilds Documentation]