If the offset between Home and the Blade is consistent: - HOME the axis - Jog it to the Blade (Work Zero) and click SetZero Thats it. Blade...
Checkout G-Codes
TB67S109AFTG | Toshiba Electronic Devices & Storage Corporation | Asia-English - very good drivers, reliable and strong. Configured to 1/8th...
I'd recommend handling that in your host software. Move 10mm, do what you need to do. Move next 10mm. Send commands when needed, watch position...
BlackBox provides standard 3.3v PWM or 0-10v Analog signals. See the BlackBox Documentation https://docs.openbuilds.com/blackbox-x32 For the...
Or false trigger caused by EMI docs:blackbox-x32:faq-emi [OpenBuilds Documentation]
There is, but connecting to a PSU while the PSU is powered on means instead of a nice soft start from the PSU (sees reverse blocking diode, PSU...
Sadly not. In a soft start, it survives, but that sparking marks are indicative that power was on at the time of connection, blew up crowbar diode...
Incorrect polarity wouldn't necessarily "go negative" as long as you hold the probes right (PSU side wiring correct, probes correct, measurement...
Just glad you found it. That sounds like quite a hunt! Well done No apologies needed! Frustrating one that was for sure, deep in not obvious i...
Normally open switches expected Homing is enabled All switches at Axis Maximas for all axes Not related to homing and troubleshooting tab, but...
Post pics of both ends of the new cable, lets help check polarity? If its not that happy to check any other wiring/mounting pics for you too so...
The melted pin tip on the connector, the symptoms etc points at likely a reverse polarity wiring (or upstream short) - quite possible a mistake...
Grbl like this has no per-port settings. This is either wiring or damaged switches (ramming into a switch can damage internals)
Use troubleshooting tab, test switches by hand. Make sure that they all work, but also that the correct axis lights up (didn't have X plugged...
Too hard to read and missing info Use the BACKUP SETTINGS button on the toolbar...
If you arent running our Limit switches (they have onboard filtering) it might be the easiest win yes. If you have your VFDs mains cable running...
It is, IF the controller is wired to the controller correctly (0-10v vs PWM depending on what that spindle needs as there are different versions...
Thats the old 4X docs [ATTACH] X32 does not have all those sections (Slave driver not a jumper anymore, relay not a jumper anymore, RGB LED...
The older BlackBox 4X Documentation? Sounds more like a newer BlackBox X32 (read the right one's docs) On the X32: Relay1 = tool enable Relay2 =...