Ok thanks for confirming, good to finally work on the step 2 checklist thanks Then next up Any hard tugs or similar, that could have unseated...
Good to see its now unplugged, but if it was plugged Interface wouldn't have access to BlackBox. Only one host (PC or Interface) at any given...
How sure are you you are measuring the correct terminals? "DC spindles" (various models, various inputs, various levels of quality) - some might...
Yet still plugged in: [ATTACH]
Then that concludes messing with firmware you are done. No more. Step 3 (prematurely) done and dusted Now back to Interface Docs. Check Section...
Search on forum here should have some, Grbl settings = stock default. Wiring = whatever the spindle documentation tells you
You haven't answered my question. While its booting up, what version does it show (not that this matters as its not related to the error in your...
Lots of possibilities, first guess: wireless mouse/keyboard used for sending jog command / clicking jog button?
Wizards and tools > Calibration - his steps per mm is off - the Grbl Wiki is a must-read Grbl v1.1 Configuration Or you accidentally set $13=1...
almost never, just follow the instructions docs:interface:firmware-update-control [OpenBuilds Documentation] (You should be putting into...
Will make it "more" accurate (ours was already like 0.004mm so won't be noticable) - but the slowness will be frustrating, and on some jobs a...
Spindle startup up just before the G4 pause which waits for spindle to come up to speed right? So spindle spits out EMI and causes a false limits...
Theres no real locally stored anything worth a reset. Not 'resetting' things wouldn't change much. Its not a case of "something stored wrong"...
THAT jumper is inside Interface (: You weren't even inside the right one (:
Messing with the jumpers earlier - possibly related. Autoreset is in relation to the USBs DTR/RTS handshake
Ours is 8mm (: 3mm screw will be 3/8th the speed of ours, but also 8/3x more torque. Our 8mm has more than enough torque, so its not that you...
PWM output is 3.3v. If you wired the PWM output to a 0-10v input, it would have been damaged, explaining the always on state. Can also be damaged...
1) Setup steps per mm correctly (without Soft limits Enabled - it will move 1000mm per click max) - calibration must be far off if 1000mm looks...
Always best to stop the source from emitting the harmful radiation in the first place... Grounding/shielding tries to stand between the source...
Reset button, on the side of the Interface. Give it one quick click to reset/reboot That is two very seperate processes there... You are mixing...