Separate names with a comma.
Some features disabled for guests. Register Today.
OpenBuildsCAM is 2.5D only. For STLs you need a 3D CAM like Fusion or Vectric, etc: docs:software:overview [OpenBuilds Documentation]
You don't have to wait for an alarm to be present. Can click Unlock and Home as usual
Ctrl+Shift+i to open Devtools Go to the Application tab [ATTACH] Go to Storage > Localstorage > localhost Scroll down to macroButtons [ATTACH]...
The limits you were having trouble with. Inductives needs voltage divider or reverse diode, limit switches can be wired wrong too. Also so we can...
Post pics of wiring if you need us to review
Arduino, with NO switches = $5=0 Sure you wired correct pins (Using a CNC shield? Cheap Chinise Chinese knockoff clone with the Z switch on the...
Likely differences in Grbl Settings: Check that $40 is the same on both (If running X32s - should be $40=1) otherwise check Max Travel values,...
Do you have BlackBox X32? If so make sure $10=511 (Required to make all the reporting like DROs and the Troubleshooting tab work)
Not really but that Grbl wiki tells you all you need to know. Inaccurate calibration means something else (acceleration/max rate, or physical like...
Negative, not related The only thing that can change settings, is the operator. Welcome to review the code changes yourself if you believe it...
If your connection attempt does not reboot the controller (We have recently changed some code in that regard to better support devices with native...
Especially Xtension Limit Switch Kit (and little known fact, more repeatable than inductives - they drift quite a bit depending on the flux of the...
Read the entire Grbl Wiki.. All of it. Even the boring bits. Its a goldmine of valuable info of what Grbl expects from you Home
CAM only works on Closed vectors at this time. For advanced options one might need to upgrade to more advanced CAM like Fusion360 with our post...
Correct Leave the 0-10v as it is, we know it work Cannot confirm correctness. Never had one of those across my desk, no writeups, manual in...
Why? See Yours is already different from the the example, so go with what I said later on (only - nothing extra, no relay1 anymore, you don't...
Along with Yes Its always been an option. On GOOD VFDs just not needed. Thus the mention, check with your vendor if they support the good...
So if they don't support 2 wire mode like the less cheap VFDs, then wire the relay as suggested above too
Refer your VFDs manual, or ask the VFD supplier to support their product Quick squint at the manual, around Page 59 - 2 wire mode...
For example [ATTACH]