Separate names with a comma.
Some features disabled for guests. Register Today.
Well, from here, i see the margin of error in placing that second switch and then relying on the switch to be far inferior than to jog the machine...
Well, if there's anything for autosquare to correct, the machine wasn't square right? Applying that correction, means something that was bolted...
You can enable it in the grblHAL Web Builder. Wire the Y2 switch in Parallel with Z and ensure Z homes on its own ($44=4, $45=3) (Sharing with Z,...
Wire them as shown in docs:blackbox-x32:connect-micro-limit [OpenBuilds Documentation] except using the NC terminal instead of NO - and just...
OK so reverse engineering off the pics, you had Blue = GND, Brown = V+ and Green/Yellow as SIG On the Inductives, you have the typical Brown,...
I do check forum over the weekend so please do - Pics of the X switch wiring etc - Troubleshooting tab without X triggered and with X Triggered...
and Are both very solid clues that Is going to cost you a BlackBox. There's something there. 3rd party components, incorrect wiring, etc can...
CAM > Settings tab > Changelog button to see what's changed when [ATTACH]
As you mention Pull Back - I'll assume you Homed? So X limit switch is shorting! Check wiring mounting etc
That CAN kill the BlackBox! So double check ALL WIRING! (Removing the short and still having an alive box is already luck, don't reconnect...
Correct. As you would with any CAM. Create GCODE > Save it Then go to CONTROL and open it. I think about the only place the Transfer button /...
Only enable Homing on that axis and don't enable Hard Limits on that axis (:
Mostly CAM setups. Use our Fusion Post or OpenBuilds CAM Search Results for Query: Plasma. Ihs | OpenBuilds Did you watch Dr D Flos video? Bit...
Follow the onscreen instructions where the old button used to be.. Video is a couple years old
You want $5=0 if all the switches are NC
$5=7 is for Normally Open switches See the line just below the Important Warning on docs:blackbox-x32:connect-micro-limit [OpenBuilds Documentation]
Pictures of machine showing switches locations full grbl settings backup for review (CONTROL > Grbl Settings tab > Backup Settings button) Highly...
Make sure $5 is correct (use Troubleshooting tab to test switches by hand) What exactly happens?
Does your gcode contain a spindle off command at the end? Is the IoT wired to Tool Enable or Tool PWM? Is it a BlackBox or some other controller?
Yes.. The 1515 is a big heavy machine. Solidly (reliable) while fast enough for standard work. Always room for tuning, but i mean don't expect to...