V1.0.370 is the latest at this time
You said you had a spark, so its possible Only other thing it could be is drivers docs:blackbox-x32:install-drivers [OpenBuilds Documentation]...
Conflicting information: Your very first post: You already confirmed you plugged it into the same PC that killed the 4X so it is likely already...
Spindle is FINE :) (repeated several times above in thread) Stop focusing on the Symptom As above More importantly This shows the DC side of...
Continuous Jog + probe for final position is a luxury you won't come back from.
Shield should be grounded. That's the point of a shield. The Sparks rather indicate a midwiring somewhere shorting to GND
Awaiting these results
docs:blackbox-x32:faq-identify-motor-coils [OpenBuilds Documentation] has a guide
1) BlackBox firmware up to date? (Section 7.1 of the BlackBox Documentation) 2) test Probe wiring on Troubleshooting tab (touch plate to clip,...
Just to confirm, you are using the Tool On menu? Any miswire/shorts earlier that could have damaged the PWM port? (disclose is always best,...
Correct for an X32 Repeat tests from #17 but check status in Troubleshooting tab (where possible) instead of the LEDs
Weirder. What do you have in Grbl Settings under $6 Probe Invert
Probably not related, but you recently replaced the VFD. Why? What happened to the old one?
No thats a valid and required earth path; spindle body MUST be earthed. You are attacking the symptom not the cause. Reply to post #17 accurately...
Right, so process of elimination. Keep probe clipped to collet. Green lights on probe plate is on right... Keep BB powered off USB, and unplug...
Again, the VFD isnt the issue, nor related - the question "do you have a VFD spindle" was important because VFD spindles have earthed bodies,...
You may need to look into what a VFD does a little more (: - but no. The VFD isnt the issue. The short circuit "somewhere" in your system as a...
Process of elimination as a start. Somewhere AC GND is shorting to DC EARTH - these should be seperate domains. Machine will work "fine"...
Edited in information afterwards... We only get notifications on replies. Edits go unnoticed [ATTACH] So, per post #3, then if it has a VFD,...
Awaiting replies to post #3?