Stick to good software, like CONTROL for setup work. 3rd parties doesn't always know what our machines and our controllers needs.
Yip resets cuts the Enable. Remember to rehome if needed. Restart needed because some Grbl Settings take effect at start up. During restart...
Computer specs?
Did you remember to load machine profile? CONTROL up to date on V1.0.370 > Grbl Settings tab > Select machine from the list > Save and reset when...
Should be able to. Never came across a VFD that couldn't be configured properly to just need 0-10v signal yet
Good check, yes, make sure to try docs:interface:fat32format [OpenBuilds Documentation]
Does the drive included with the Interface work? If it does, it might be incompatible drives in some way, but if the included one doesn't work...
See Tramming: A generic guideline
If you power up the laser, and measure the wires you had plugged into the PWM port, what is the voltage on there? (not BlackBox side, but Laser side)
You'd also make the support teams life hell, theres good reasons we provide updates, please do stay up to date (or consider not asking any...
Check mechanicals first (grubscrews on shaft couplers, pulleys, stop collars, etc amongst others) Then run CONTROL > Wizards and Tools > Calibration
Can use it. But something in VFD setup could still improve because its not needed what set up correctly
A properly setup VFD just needs 0-10 signal. Stops when commanded to go below 120hz (7200 RPM min for air cooling to work properly).
Example you can modify in this thread higher up i gave you earlier. See post # 11
You forgot to setup MinFreq in VFD parameters
See post #19 above for the link (right above your question)
Its free so give it a test. Use the search above for Bitsetter, there is a Macro
Touchoff should be a Probe not and Endstop
We provide the standard 0-10v signal. Everything else is VFD manual / VFD vendor side - i.e how to configure your 3rd party VFD to accept an...