Separate names with a comma.
Some features disabled for guests. Register Today.
If the purpose is for min/max endstops, then yes. See...
Checkout Additional or extended settings for most, rest often documented in the respective Plugin's repo $7 controls whether Relay1 stays on or...
If you have 110 nearby, even better... Both outputs the same 24v
Our PSUs can run on either, see Step (1) of docs:powercase-v1.9:start [OpenBuilds Documentation]
Please continue with your existing support ticket at support.openbuilds.com - our agents are already in conversation with you. Thanks
Yes, using an Inductive as a Probe is not documented (they tend to have too much drift to really be usable as probe in the first place) but the...
And as per section 3.4.3 of the BlackBox X32 documentation: docs:blackbox-x32:connect-npn-inductive [OpenBuilds Documentation] should be NPN NPN...
Note that is one for at the time the file is loaded, if you want it during the job, you'll need to write your own macro, and it would be more...
With a custom macro, all things are possible: Can OB Control Software pop up a message if it detects specific code in the GCode file?
Can't directly comment on a 3rd party controller. But in our BlackBox you'd have the plate as GND, the Magnet as SIG (With a 5v pullup) When...
When working on antiques or things you cannot surface, design inlays to be cut with straight bits. No V-bit or tapers.
You have to connect it to the Blackbox first Follow the documentation step by step. Wifi setup is the step AFTER connecting it. Successful...
XYZ Probe Plus with VFDs and other ground-loop inducing components Finding and eliminating the bad wiring is key. How are you measuring? No...
That's just a Z probe. No need for it. XYZ probe can do Z too. Click the Z tab in the wizard. If its not on a spot you can use the corner,...
Depends what kind of probe, what you expect to use it for and then of course the Wizard does what it does, nothing more - are you up for creating...
Checkout video below to learn how to build the correct type of floating head with a probe switch etc [MEDIA]
Yip would be a waste of time. Control reinstall won't change a thing. Either wired wrong, plugged in wrong, router switched off, or something...
What about looking into G28/G30? Set stored position to align with grid. Home, then Goto G28 or Goto G30 [ATTACH] That way it doesn't interfere...
Use a combination of your VFD manual and the info on docs.openbuilds.com/blackbox-x32
Pull of doesn't change the position of Mpos:0. Pull off just "pulls off the switch to avoid triggering it". 0 is ALWAYS set at the point where...