Separate names with a comma.
Some features disabled for guests. Register Today.
yes, use the same spec as the OB motors. or very close to it. Peter has explained why a million times , inductance, current and voltage matter.
Then it is EMI, but the reason for wiring NC is to prevent EMI giving false triggers, so that is unlikely, much more likely is the movement is...
probably a wiring fault on the X that is disconnecting the switch. That is the benefit of NC wiring, any faults will show up as a trigger.
feedrates depends on the cutter rpm, the material, and the machine stiffness. a good stiff machine should be able to cut cherry at 180 inches a...
wait, wow, your feedrate is 1" a minute, and plunge rate is 1/8" a minute. are you cutting granite? (-: so, upshot is the roundoff it making...
I did try it here myself, just cut an outside circle and I get (Generated by SketchUcam V1.5c-fc1fbff) (Bit diameter: 3mm) (Feed rate:...
please upload your sketchup file so i can debug it
upload the gcode file here so we can check
1000 or 1200va, 24v battery pack. a lesser va will do the job, but will not last long (esp the 12v battery ones), and if power goes out for 3...
[MEDIA]
the Mega does not have 10v output, you will have to find a PWM to 0-10v converter and wire it up. unless your VFD can take 5V PWM input directly?
I always use one of the locating pins as x0y0, and table surface as Z0 for the second side, then material thickness no longer matters so long as...
you have missed the 50 or so messages in the forums saying "turn off soft limits' (-: since you have changed some GRBL settings from the...
the limit switch/s is perhaps mounted upside down, or otherwise such that it is connecting power to ground when it is hit, thus causing the BB to...
no binding, did you read the error message? it said 'error 3 reset while in motion', binding will not cause that, but wiring/power supply/EMI...
for plasma, laser mode must be disabled then in Fusion360 you need to enable smoothing and set the value to a useful amount, try kerf width as a...
well you see, it depends..... I am going to assume you mean home, since we usually say 'zero' for where we are going to run a job, which is set...
i woudl mount it with X vertical, and just park it at the bottom before power off so it cannot fall
how did you get to that number? 6:1 gearbox?
never plan layouts until all the stuff is on-site (-: