The FAQ is quite comprehensive, is nothing brings it back, likely damage per Section 6.3.1 of same. Do make sure you did all the tests Like using...
They are always quite happy to help https://www.deskproto.com/webshop/contents/en-us/contactus.html if you get stuck Been a while since I did it...
1kwh usage, 6.5kwh available = theoretically 6.5hr. Lots of variables though so don't hold me to it (load on router based on cutting recipe -...
Up to 800w for Router, around 200w for machine. +-1kWh- will drain most of those banks in not a lot of time (check kWh capacity of bank)
Always here to help. All wiring covered in https://docs.openbuilds.com/blackbox-x32
Can use either, the gcode must just tell the controller what its in (G20 or G21 in gcode to match) which those posts will do for you
Load the LEAD1515 profile (CONTROL > Grbl Settings tab > Select machine from list > Save and Reset when prompted just like you loaded the 1010...
Checkout the VFDs manual or contact the supplier purchased from. BlackBox provides the industry standard 0-10v signal. VFD is configured to...
Use a proper DXF editor and check if you have them converted to Polylines. See demo with Qcad here...
Checkout https://docs.openbuilds.com/doku.php?id=docs:software:file-errors Radius inversion means that radius is an Arc not a Polyline. Convert...
Coolant would be the better option yes, you are correct the relay is not meant for a) use with PWM (Same output, relay will chatter) and b) mains...
Wire up SIG and GND on an input and close SIG to GND (touch two wires together) to simulate a normal switch...
We still have it https://builds.openbuilds.com/mirror/sketchup/
"random" wiring (swopping things just because) is a little reckless and a quick way to destroy a controller (might already have damaged input...
Remembered to move the voltage jumper? https://docs.openbuilds.com/doku.php?id=docs:blackbox-x32:connect-npn-inductive (See TIP section at the top...
Try a DUET Post - different controller, different dialect, it doesn't run Grbl.
Any chance you have an IoT relay for the spindle? And if so, any chance you mistook it for a power strip and also plugged your 24v PSU into it...
Check how much current laser module draws in their specs and refer https://www.omnicalculator.com/physics/dc-wire-size
If its the same PSU for BlackBox and Module, then yes, just one wire off PWM+ (GND already there from PSU) Always happy to review wiring with...
Essentially BlackBox provides a 2-wire (GND+SIG) PWM signal (3.3v) Power for the modules comes from either modules own PSU, or if its a 24V module...