Extinguishing arc is usually related to - air pressure too high - worn consumables - cut height too high - wrong consumables (using drag cutting...
Relay 1? I do hope you read what I said above. Can, but shouldn't. Hoping you did not skip Min Freq config. Will refer you back to conversation if...
Most likely a wiring mistake or similar thus the request for wiring pics. There are differences between the two specially around toolhead wiring....
Sounds better. Dont mess with the defaults. Those others are for Servos (documented here docs:blackbox-x32:connect-rc-servo [OpenBuilds...
That is somewhat similar here, so lets bare it in mind as we continue Stock standard is a good start (5000) or could try 1000. Profiles doesnt...
Preferably all wiring, not just PSU. Whats the other device wired to the Power Supply?
See section 3 of Terms of Service and Rules | OpenBuilds as provided during that threads moderation action [ATTACH] Now, Section 14 also...
Indeed, we do warn about it right there before you go flashing too: [ATTACH]
Reboot PC
And thats with VFD disconnected? Any other Grbl Settings changed from defaults (like for example the PWM freq etc?) Using a good clean power...
Reboot the computer. If its still doesn't connect, reflash with stock firmware. Flashing can't break anything. Double check that you are on...
No, just explaing the relation between 0-10v scale and what spindle should do (and why $31 should be 0, to let the VFD handle the minimum startup...
Grbl settings should be $30=24, $31=0 (Else the scale will be all wrong. 0V=0RPM, +-3.3V=7200RPM=turnon, 10V=24000RPM)
Thats indicative that the VFD's "Min Freq" parameter hasn't been setup yet or correctly. Air cooled have a minimum RPM of 7200 rpm (below that...
Please post pictures of wiring, power supply for review
OpenBuilds-CONTROL/app/wizards/interface/PROBE at master ยท OpenBuilds/OpenBuilds-CONTROL has a couple
docs:blackbox-x32:faq-emi [OpenBuilds Documentation] but with VFD specifically, main thing is to "stop the VFD being nasty" rather than "lets...
Induced in signal wire yes. But Power/GND present in bundle too, EMI induced electrical noise causing ripple on power rails... Other problems VFD...
Definately the older driver then - you should use the newest ones they handle DTR/RTS (autoreset handshake on connection) correctly. Removing old...
This thing [IMG] Is the IoT Relay IOT Switching Relay Power Strip And ONLY the Router should plug into it. Move the other plugs to the wall...