Ours is 8mm (: 3mm screw will be 3/8th the speed of ours, but also 8/3x more torque. Our 8mm has more than enough torque, so its not that you...
PWM output is 3.3v. If you wired the PWM output to a 0-10v input, it would have been damaged, explaining the always on state. Can also be damaged...
1) Setup steps per mm correctly (without Soft limits Enabled - it will move 1000mm per click max) - calibration must be far off if 1000mm looks...
Always best to stop the source from emitting the harmful radiation in the first place... Grounding/shielding tries to stand between the source...
Reset button, on the side of the Interface. Give it one quick click to reset/reboot That is two very seperate processes there... You are mixing...
Section 5.1 of BlackBox Docs docs:blackbox-x32:aux-serial [OpenBuilds Documentation] For Interface to talk to BlackBox you only need 1) Cable...
Yes, can leave it that way
If its like an Exclamation mark or one of the others that double as a Grbl Command see Can’t get blackbox x32 to save updated settings
Do a test again..circle diamond square with caliper measurements. Pics of the machine too, lets see if something looks sus. If you hold the tool...
Duplicate of Ask Grbl CNC questions here. closing thread. Continue existing discussion thanks
Cut bevel is not EMI. Torch straight? Cable not pulling on torch causing it to go off square in mount? Then consumables changout time :) Ask the...
Thats just the input field - we don't bother "remembering" all values because once the gcode is created you take it from there as a Job. Wizards...
Honestly that question would be better answered by the Plasma's vendor - they designed in a terminal, so I am sure they'll be in a better position...
Not the phone side... The PC doesn't have a valid IP (usually more like 192.168.x.x or 10.x.x.x for consumer stuff) try a reboot, make sure PC is...
Provided you did get calibration accurate (within couple steps of theoretical value) then it really is still mechanical. Keep looking :) Sadly a...
169.254.x.x looks like an APIPA address, What is Automatic Private IP Addressing (APIPA)? You need to make sure your network / DHCP is working...
calibration = once off correction for manufacturing tolerances. Doing it over and over again, is hitting the wrong track This is mechanical....
Grab a screen recording, maybe we see what you are doing wrong? Are you sure you are TYPING into both fields (not just looking at the empy block...
Same response you posted yesterday, scroll back up and have a look
Sounds more like calibration. Wizards and tools > Calibration > Y axis [MEDIA] And make sure you Zero correctly, If you you set origin as top...