Sounded like a stalling motor there when it had to center on X. Stayed off to the side there. Max Rate / Acceleration tuned too high? Negative...
[MEDIA]
By that question, I guess we can assume you haven't read the required reading yet? Grbl v1.1 Configuration
$100=133333.000 ; X-axis steps per millimeter $101=133333.000 ; Y-axis steps per millimeter Probably that. Way to high - those numbers...
Cool, awaiting your grbl settings backup for review
Grbl settings backup for review: CONTROL > Grbl Settings tab > Backup settings button Any 3rd party (not from OpenBuilds) components on the...
Yes, it should. 1) Check your calibration and 2) Check that you were probing correctly [MEDIA]
None at all. A relay has two dry contacts that CLOSE together when triggered - thus no "signal". Its used as a switch to connect to wires together...
Please contact the vendor you purchased from for assistance. If they are unable to assist, consider getting a BlackBox X32 (see...
Section 3.3.1 of the BlackBox Documentation "can" be used with some VFDs but due to the variances in VFDs, terrible Chinese translation...
Good to double check..some has it as a jumper
Did you correctly install the collet into the nut first? They do work a little different from woodworking collets that you slide into the taper...
Watch out for that one - make sure jumper is on the 0-10v mode, if its on the 4-20mA position when you wire up the 0-10v it could damage the...
It should at least describe the terminals somewhere. Parameters pages should list things like frequency source : external terminals etc. A quick...
Refer to the VFD manual to see how to wire up the industry standard 0-10v signal
No, our stock profiles doesn't change those, you can review our settings at OpenBuilds-CONTROL/app/js/grbl-settings-defaults.js at master ยท...
Always hard to review a Grbl Settings backup (if only people would leave defaults or tell us when they changed defaults lol), but ran yours...
Contact the store via Support > New ticket for further assistance, thanks. Include link to this thread
Did you change the default? The 24v PSU is connect and on right? (derives the 10v rail off the 24v supply) Any earlier miswirings or shorts...
$30=25000.000 ; Maximum spindle speed, RPM $31=0.000 ; Minimum spindle speed, RPM That's correct. Dont change the minimum, that will just...