Separate names with a comma.
Some features disabled for guests. Register Today.
You can change the output in Vectric's post to be whatever you need it to be. 1000 is the default (as $30=1000 in default grbl settings) but your...
Grbl Setting = 0 (as you want 0v-10v to be 0rpm-24000rpm) settings it to something else messes up your scale The 7200 min is set on the VFD! So 0...
Sales coming up soon, sign up on Newsletter to be let know when that happens OpenBuildsPartstore.com ships internationally Shipping and Delivery...
Correct way is GND and 0-10v only, setup the VFD correctly to stop/start based on Min Freq
Either wired wrong, configured wrong, or EMI. More importantly the Door input is for a Door switch. E-stops shouldn't be connected there....
Correct, try that first
What is the value of you $376 setting in Grbl Settings? $376 - Settings_Axis_Rotational Designate ABC axes as rotational by \ref axismask. This...
Yes, but do you have anything wired to the DOOR port? An estop, or similar would count too. Anything wired? Or perhaps nonstandard Grbl Settings?...
Did you remember to Zero the A axis prior to starting the job?
Anything wired up to the Feedhold (Door) input?
Sure its the correct Post? docs:software:vectric [OpenBuilds Documentation]
not at this time. Anything specific you wanted to know more about? Just about everything is covered in the docs docs:blackbox-x32:layout...
Typically they are all terrible. DQ/DM542 are much nicer, not much more Best option though: docs:blackbox-x32:start [OpenBuilds Documentation]
4.2A is the MAX/Peak rating, not the recommended setting. It will overheat and stop working if you run it at 4.2A. In the same way your car...
Double check the S-values in your GCODE - did it send S18000 or S24000 Double check that you did calibrate the 0-10v:...
Jumper only applies to powered switches / sensors
You left CUT DEPTH START "empty" - set it to 0 [ATTACH]
Post the WORKSPACE export for review please. File > Export Workspace OBC.
Alternatively, instead of writing commands, you could modify the Saw Stop macro to be a Press Brake Backstop macro. Getting started with...
Login is for support agents. As mentioned, New Ticket is for you, and then of course just sit tight and wait for the store to get back to you,...