You can set global variables yes Window Variable JavaScript | Declare Global Variables inside a function We don't impose any limits. You can...
Feature has been disabled. Use the Save Gcode button provided thanks [ATTACH]
The grid expands to the size of the gcode (it has no clue of your stock dimensions, as the gcode doesn't extend to the unused edges) Go for it
Should be fine. Just don't switch the full spindle load itself
That is non-standard and from GitHub - TGit-Tech/GRBL-28byj-48: Grbl ver 1.1f.20170131 with XYZ Unipolar Stepper Support (28byj-48) You may need...
Soft Limits is not currently supported by CONTROL on the X32 - keep disabled (as per our profiles)
Relay 1 is by default Spindle Enable and Relay2 is by default Direction. M3/4 switches Relay1 on, M5 switches it off M3 puts Relay2 in one state,...
Since standard Grbl doesn't support drivers like ULN2003, which fork of Grbl are you using? Perhaps they broke the $3 implementation and you'd...
Not in our docs. You had a mosfet in your Diagram that was missing its resistor. Could cause damage the the BlackBox's microcontroller. MOSFET...
Check the Hello World to make sure machine is not mirrored: docs:blackbox-4x:hello-world [OpenBuilds Documentation] Surface workable area only to...
Don't forget the resistor between MCU pin and base/gate. Onboard relay1 is already an Enable too so might save you extra wiring
Adjustment has a range of around 8-15v yes, overkill, but flexible for nonstandard uses. The bottom end may float a little - as VFDs (the...
CONTROL as in OpenBuildsCONTROL(tm) docs:software:openbuilds-control [OpenBuilds Documentation] which you download from software.openbuilds.com...
Thanks yes, thats clearer to understand If you now connect to CONTROL and send an M5, does it drop down?
Not all straight no. But somewhere a straight little section that meets the required distance to fit a tab with the parameters you provide (which...
In this config, BlackBox is off-off right (both power sources removed) - so that voltage must be backfeeding from the Spindle PSU? Or faulty...
Vs Are you questioning Simulation or Running the actual job? Conflicting part of the question there as its two very different things. Simulation...
Sim's just fine for me... Make sure to zoom in so you can see it, its a large job [ATTACH]
Have a read through Grbl v1.1 Configuration and check what yours is set to
Post the gcode file too please (Save button on the Gcode Editor tab)