Exactly how we recommend it. First IoT handles spindle on M3/4/5 docs:blackbox-x32:connect-dewalt-iotrelay [OpenBuilds Documentation] Seperate...
From your first post.
Use a second IoT on the COOLANT port. As documented in the Blackbox documentation. Then in your gcode add a G4 P10 between the M3 and M8 commands...
Make sure you have Report Inches set to 0/disabled in Grbl Settings. CONTROL handles imperial conversion internally
Soft Limits in CONTROL depends on default Grbl config of having the machine in negative quadrant standard. Try a less invasive approach first...
See section 1(c) of docs:blackbox-x32:layout [OpenBuilds Documentation]
Plastic is typically the problem. It needs earthing.. Refer the link provided above
Built into latest OpenBuilds CONTROL (Grbl Settings tab) or see the grblHAL repos on GitHub
In the meantime, a couple cheap flash drives (per-job, nicely labelled) could help them be more organised too. Rather than lots of different jobs...
Check out docs:blackbox-x32:faq-emi [OpenBuilds Documentation] Earth the vacuum hose to dissipate static
Lets continue that discussion in your thread at USB Connection Error when the time comes (: easier to track a conversation in one thread...
Next time it happens, grab a screenshot (we use CloudFlare Anti-spam, but not "blocking" people per-se, it looks at behaviour). Pulled up your log...
Thanks for the suggestions
Grbl flashing instructions: Flashing Grbl to an Arduino
Not blocked (if you were you wouldn't even be able to login plus would have received an email telling you you were blocked along with the reason,...
No, no limiting or anything like that
You cannot use HF with a CNC
OpenBuilds ACRO System has the original designs in sketchup (Files and drawings tab): On that I get 59.2 centerline, 60.5 at max. As it is...
The original plates are slotted - the centerline of the slot should be just perfect, but has a couple millimeter each side to compensate for any...
It does work fine - but as the software and docs has to cope with new and old controller customers alike the wiki caters to both controllers. You...