Yeah space the VFD away and run its cable through a swing arm (not through the cable chain along with limits etc): Swing Arm
So far looks like you dodged the worse of it (; Checkout the docs if in doubt, and then of course other sometimes forgotten tips like don't spin...
Not just the RATTM, all of them! Unless the manual says its a 5v input. Always best to follow the docs: - docs:blackbox:connect-vfd [OpenBuilds...
Followed by Was what alerted me. X1 seems to have a 24v pullups (from the VFD not the BoB) as most VFDs do. Some has a jumper for pullup voltage
Hard to say, we'll see as it goes on
Possible, but from what we observe so far things seems to be working.
That's how we deal with it. Panel mount "safety" switch to take it out of RUN mode for toolchanges, etc, switch to RUN mode rest of the time. M3's...
Great, so the voltage you see is likely an internal pullup on X1 The Relay (and subsequently your jumper wire / ARM/RUN panel switch should thus...
Probably still relates to the unaswered question above ^ What CONTROLLER are you using? BlackBox has optocoupled and filtered inputs to prevent...
Is the old Breakout still up and running? What goes into X1 from the BoB? Dry contact connecting COM to X1? (After all relays connect stuff?) |...
If the parameters allows, it would be an option to remove the need. If not: Sounds like it could work
Yeah different vendors do things a little differently, but X1-5 are configurable as enabled/fwd/etc Usually a GND Or was this relay on the BOB...
Yeah understood that: First section takes the 10v from the VFD, and divides it as 0-10v going into AI1 (analog in) - thats the same now except...
M3 vs M4: one sets the pin HIGH, one sets it LOW. Its not a pulse
Yeah most people don't wire up the DIR signal. Mostly because its a 5v logic signal and many VFDs needs it as a dry contact for the input (See...
See docs:blackbox:connect-vfd [OpenBuilds Documentation] Most of our writeups jumper the enable (or wire via a safety switch) and then solely uses...
Here's the documentation for OpenBuilds Interface https://docs.openbuilds.com/interface That looks like a CONTROL error. INTERFACE's errors are...
Thats a bit fast What was your depth of cut? Come down to F1000-2000 range - start off slow and work your way up Also check your Max Rate...
At the same time: only both are Normally Open (XYZ Probe Plus is) You can give it a go as a Custom probe with Z offset = 0, and XY offset = how...
Address the source (VFD) of the interference - rather than trying to shield every possible victim. If the VFD/spindle is putting out abnormal...