Separate names with a comma.
Some features disabled for guests. Register Today.
Answer that question by analysing laser input (are you getting 0-5v? Then the controller portion is correct) Did you wire your IN/G/5V...
L is for "logic low" controllers, does not apply to Grbl based boards H is the right connection to use. Did you remember to Enable Laser Mode?...
But rather than the built in fusion Grbl post that uses confusing G28, rather use ours that uses the easier G53 concept as linked above
First up, the DOOR input is not for use with Emergency Stops 2ndly - when Grbl is in DOOR ALARM state, it doesn't report Limit switch statusses...
If its one of our machines ( You haven't provided much details, so best we can offer are generic replies) your steps per mm should be 200 for...
1) ensure Z axis is mechanically sound first - particularly check shaft coupler grub screws 2) make sure acceleration and max rate is set...
Most likely wiring break or loose terminal See docs:blackbox:faq-identify-motor-coils [OpenBuilds Documentation]
You can't tension it more by using two nuts. One nut does the job just fine. The other end is constrained by the shaft coupler, the nut adds...
Consider a BlackBox https://docs.openbuilds.com/blackbox as a more known working config with our support team on standby
See posts #26 and #27 in LEAD Lathe too
Try a standard Windows / Mac / Ubuntu 22/04 install instead
Yes, use the Wrapping function in Vectric to wrap it about the Y axis
You can still use Aspire with BlackBox: docs:software:vectric [OpenBuilds Documentation]
Depends how its alarm works. If its a dry contact relay that is "closed" when everything's OK and "opens" when something is wrong you can loop...
Grab a BlackBox (see https://docs.openbuilds.com/blackbox) and run it off USB off any PC or Mac (Win 7,8,10,11,Linux,MacOs) using our free...
That is correct yes - don't forget the interlock loop between P (for protection) and G (gnd) via NC door switches and NC flow switch Provided...
See my earlier reply
Ok cool, yes please stay safe. Fix the previous owners mistakes before its too late Mostly seems you were missing the potentiometer for G/5V/IN...
P to G shouldn't be a loop, it should be part of your door interlock switches and flow switch in a normally closed loop. Ignoring safety and...
Check the pins on the connectors of the Aux cable - a hard tug can pull the pins back and out of position - you can reseat them in the housing if...