Separate names with a comma.
Some features disabled for guests. Register Today.
See the last point of docs:blackbox:jumper-slaveaxis [OpenBuilds Documentation] and also search here on the forum. Note it is quite hard to setup,...
Update to v1.52 to using method 2 or 3 (see the firmware update section of docs.openbuilds.com/interface) - older builds of the Firmware does not...
The Coolant output is 24v. Refer docs.openbuilds.com to learn more
""
Do you already have tension? From the video I see a stop collar, not a tensioning nut? (Gotcha the seperate tensioning tool thingy) I still see a...
I think the wobbly leadscrew is making the thrust bearing move side to side a little. Needle bearings, unlike the recommended Thrust bearings from...
Replace the front stop collar with Tension Nut and pull the screw into tension. That'll pull the whip out of that slightly bent leadscrew While...
Correct Not correct (:
You can check that your wheels didn't develop "flat spots" (Can happen when set overly tight and left sitting in one spot for too long) Also...
Not even snug. Just take out any axial play on the leadscrew See [MEDIA]
See the Grbl Wiki for details on wiring on pull-ups and filter caps. The "buffer board" is overkill
Also see: Black Angle Corner Connector or depending on the use case even Inside Outside Corner Bracket Or sand the little nubs off if its used on...
Would be fine on a 3D printer On heavy loads you'd prefer the bigger wheels.
That is crazy high yes Soft limits requires homing (to know where the physical machine envelope is in virtual space) Homing requires switches....
OpenBuildsCONTROL > Grbl Settings tab > Reset EEPROM buttons on the top toolbar Otherwise:
GPU drivers if I had to guess
You acceleration feels high to me, so I am thinking we try lowering it first - and then I am a fan of changing one parameter at a time as best...
Hard to say - trial and error :) would be better - best to tune these machine specific values with the actual machine If 500 does cause issues -...
2x Steppers in parallel needs twice the amperage correct Dual drivers are the better way of doing it though. Note 3A is the MAX rating, not the...
Not quite, as G53 is not a true "coordinate system" like G54-59. It's non-modal and commands moving in G53 needs G53 in front of each command....