We don't use WebSockets, we use Socket.IO which can backwards support websockets as a fallback, but, not the intended method. The 50ms update...
The noises are a symptom of miswiring, see docs:blackbox:faq-identify-motor-coils [OpenBuilds Documentation] Either incorrect coil pairs (ignore...
Manual will tell you That just sets the mode of AI2. You still need the right parameters and wiring
Will check the attachments when I get back in the office - hard to do via mobile V= voltage loops like 0-5v or 0-10v etc I= current based systems...
At the bottom of docs:blackbox:connect-vfd [OpenBuilds Documentation] you'll find links to known working configs Basically every VFD has a Run...
Refer the VFD manual for Frequency Source and other related parameters
Haven't used SheetCAM in years, so I don't have a better post around myself. See Grbl problems - sheetcam.com though, discussion mentions arc...
Grbl supports valid Arcs yes. OpenBuilds CAM doesn't generate Arcs no, uses interpolated line segments, not as optimised, being a free, basic,...
Error 33 means the Gcode the post created is invalid and thus does not constitute a valid Arc
Checkout the https://openbuilds.com/builds/openbuilds-acro-system.5416/ Leadscrews are typically too slow for laser work
For that sort of job I'd CAM off a center point origin instead of a corner. Pencil a line from corner to corner and zero XY manually over the...
Is the motor shaft deep enough into the coupler - i.e. all the way to the halfway mark? Maybe even a little further (as long as you can still...
We've only tested up to the included length and suspect longer will suffer from signal slewing, EMI and all other kinds of problems
Remember torque isn't everything. Inductance, Resistance and Coil voltage parameters affect the "feel" of motors too - how they accelerate, what...
Check size traces the extent of your GCODE (min-x to max-x and min-y to max-y) That move is in your GCODE already and "check size" is correct it...
Over the years we had two types, not sure when yours was purchased. These are the "EMI hardened" ones: Xtension Limit Switch Kit Also see...
Running Xtension Limits or other switches? Could be crosstalk from motor wires to limits wiring. Seperate them apart as a test. Speeds: trial...
The "sometimes" will be in sections long enough to get up to stall speed. Acceleration setting coming into play. Max speed is a limit, if F is...
Dial back your Max Rate in Grbl settings and try again. If its set too high the motors stall - making the sound you describe
(: i'm not directly going to be able to help with that, except to encourage you to keep on learning. You got amazingly far already - you got this!