Separate names with a comma.
Some features disabled for guests. Register Today.
Please post the workspace export so we can check for you: CAM > File > Export Workspace .OBC
When you flashed the firmware, did you perhaps use the "...and ERASE settings" option? If so, restore your last Grbl Settings backup. Some of...
That much sounds right though. NC sensor will have its onboard LED on when not detecting, and off when it does - what matters is that...
In $5 yes. $5=0 or $5=7 respectively (X=1, Y=2, Z=4. 1+2+4=7) Disable Hard Limits while setting up to avoid the Alarms - get it working nicely...
Theres an existing tool offset macro in Getting started with Javascript Macros in CONTROL / Library of Macros created by the community
Well done and Welcome Back!
That's up to the operator. If you select both paths and add them to a toolpath together, and apply a pocket to both at the same time, its treated...
Use a multimeter to check the output: docs:blackbox-x32:connect-vfd [OpenBuilds Documentation]
Well It could have picked up some damage - some of the chinese VFDs barely last a year But first, stop overthinking it - until proven that that...
That random speed-up along with the other change in behaviours, was what made me suspicious - as if it lost its config. As mentioned, just check...
Double check VFD parameters, sounds like it forgot its previous config / had not been completely set up yet
That's the WORK Coordinates Remember to probe/setzero to set those 1) You are running standard Grbl (no 3rd party version, custom compile?) -...
In that case, refer the detailed procedure above
Checkout Getting started with Javascript Macros in CONTROL / Library of Macros created by the community
You cannot add DXF Points to the toolpath. Only paths/polylines See docs:software:file-errors [OpenBuilds Documentation]
Would still be the better option They know the specific intricacies of their own software better
In time CONTROL has to keep up with backend changes. We do change stuff, for the greater good. Upgrading backend to Electron 19 killed off Windows...
If something did go wrong it would have alarmed. Going into the plate and not stopping is more likely wiring/dirty endmill/etc that stopped the...
Try a different computer (or time for a refresh/reinstall of the OS on that one) Not every wrong in the world can be attributed to update:...
So per the error, it couldn't detect pulling away from a switch. 1) Homing Pull-off set to recommended 10mm in Grbl Settings? 2) used...