Separate names with a comma.
Some features disabled for guests. Register Today.
If irs been successfully uninstalled it will be gone. Try again
Sweet then a BlackBox Motion Control System X32 would make a great upgrade to treat yourself to
Double check the VFD parameters, or wire up you FWD/REV/Enable relays to BlackBox X32 On the VFD there should be a min freq config that keeps vfd...
Specifics are important there a couple that "mean the sample thing" but the minor details still have very different resolutions... Would have...
3mm (1/8 inch) - metric No such error known, so post screenshot of the actual error, maybe have Soft Limits on by mistake in Grbl Settings?
Checkout [MEDIA] Full replacement unlikely - a good adjustment and replacing a worn out wheel or so, thats just maintenance
$44/45 applies to grblHAL based controllers like the OpenBuilds BlackBox X32 - what controller do you have
You'd have to start with a mind adjustment. OpenBuilds is all about the Modular Build System. Think "lego / mechanno" We don't have "braces with...
Otherwise pass your enable wire through Relay1 on the BlackBox then
If that gcode is from fusion, its the wrong Post? Should be using docs:software:fusion360 [OpenBuilds Documentation]
Did you check the docs, same model as we do have writeups for? Yes, it does on a correctly setup VFD Post a gcode file for review, should...
Manual should say, otherwise unfortunately would be better to ask the VFD Supplier about that if the manual is not clear. They should know (and...
Check if wired COM and NC or COM and NO (embossed labelling near terminals on switch) If yours is Normally Open (COM and NO) you parallel the...
Wouldn't be the first time. Sometime just needs a new ATX PSU. Had one case where short was inside monitor (HDMI carries DC GND too)
No real need, most of us mods, just browse through New Posts Recent Posts | OpenBuilds to see what to reply to, same thread, different thread, no...
Sounds like your VFD setup skipped the MIN FREQ parameter. You want to setup Min Freq on the VFD to 120Hz (7200RPM) so its shutdown from 0-7200...
Sounds like a plan, as long as the gantry is 90 deg to the Y axes: Tramming: A generic guideline
Could be docs:blackbox-x32:faq-identify-motor-coils [OpenBuilds Documentation] - loss one of the 4 motor wires continuity throughout - sudden...
Check troubleshooting tab in CONTROL instead, lights are on the probe itself (all internal circuitry), doesn't prove signal wire is intact all the...
Yes spacing is important see docs:blackbox-x32:faq-emi [OpenBuilds Documentation]