Yes. Its called auto squaring. Keep in mind its not as simple as setting both switches equal distance from the end of the machine. You'll have...
I have a bunch of custom stuff in mine, but this should give you an understanding of what it saves to the application. [ATTACH]
Yes. GRBL settings on read from the controller. (everything you see in the grbl tab) Chromium is the 'browser' that Control runs. It saves some...
The config is stored on the controllers. No need to load them. Macros and settings like what probe you are using are stored in chromium so you...
You need to set your steps/mm. Use the calibration wizards in the Wizards and Tools menu.
If you're on the XYZ probe tab (look at the tabs up top), then that's how it works. It move from the hole to the middle of the plate. Then moves...
Did you go through all the troubleshooting steps? docs:blackbox-x32:faq-usb-connection-failed [OpenBuilds Documentation]
My guess is that you've clicked the macro button several times and its loaded the function several times. Its meant to be run once at startup, so...
Oh Sorry. I turned of notifications for that thread. I used what peter said and only added auto square. It works great.
Add this to the bottom of the macro I gave you $('#consoletab').click()
Tab numbers have little to do with it. They are just names. Control does "start" with the console tab active. So Im assuming you mean after...
Another option is to display all the comments when you load the gcode file. In your other post regarding comments in the post processor, you have...
Yes. This line (Toolname Fresa a candela (6 mm 1000 800) PASSATA 2.5 mm) Needs to be (Toolname Fresa a candela 6 mm 1000 800 PASSATA 2.5 mm)
I can only guess that you have something in your tool notes that's causing the problem. Probably multiple parentheses which isnt allowed. In...
Can you be more specific? What exactly do you want?
I havent fully tested this, but should work. Put the following code into a javascript macro and set it to run at startup....
Wizards & Tools -> Job Log
If you're using CONTROL, use the calibration wizards in the Tool and Wizards menu. Calibrate using the longest distance that you possibly can.
Click on Advanced, then select the one you want [ATTACH]
OpenBuildsCONTROL > Grbl Settings > Scroll down to $3 Direction Invert and flip whichever axis is mirrored's switch, click Save, click Reset when...