Separate names with a comma.
Some features disabled for guests. Register Today.
Would those errors only show up when using the interface? The light burn program runs its program without issue? cutting out full run numbers...
version 1.57
I have my lightburn and cnc setup such that functions correctly when lightburn is running the show, however when I export gcode from lightburn...
The firmware is up to date. I received a replacement x4 and the pause issue has seemed to resolve itself. When using the machine the x32 was...
Using a multimeter I confirmed that the NO limit switch reads as open when signal and ground are read. We are receiving a blackbox x4 today, and...
Whenever I hit the pause command when running a job on the BlackBox x32, CONTROL v1.0.364, and attempt to resume the job by hitting the play...
Bench testing stop switches today to determine if they all somehow failed/shorted at once
Motors have been wired correctly, motors are OpenBuilds, PSU is Openbuilds and wired correctly. I tried turning the current up and it gave me a...
Would increasing the voltage to the motors stop the shaft movement when attempted by hand and when the motors are powered on?
I tested on desk, off of the machine, motors move as expected. Re-attached motors to the system and they still only wanted to move in one...
I identified motor coils and confirmed continuity at both the motors and right before entry into the black box x32. I confirmed the grubscrews on...
When it fails to move up, it does a quarter turn down. When it moves down, it's smoother.
On Friday I resolved a loose connection on the nema23 which resulted in the motors only running in one direction by confirming the coils had solid...
I'll give this a go The product states normally open: Normally open mechanical limit switch
I believe we have these ones...
I currently have third-party switches that on the x4 had functioned normally/as expected and lit up when the machine was powered on to indicate...
I have resolved the Nema 23s motor issue. Loose wiring at a wire extension position
I am unsure what caused the x4 to die. We purchased the x4 in 2020 and we had slight intermittent problems that a power on-off cycle would fix....
updated global setting, still no response from limit switches [14:45:47] [ ] $0=10.0 ;Step pulse time, microseconds [14:45:47] [ ] $1=255 ;Step...
I am using the direct CBEAM machine settting from drop down on OpenBuilds Control V1.0.355. Only change made was $4 to a 0 to get motors running