Thanks Peter, The unit is about 4 years old - but hasn't been used for 3 of those years, as it has been in storage. The version 2.6 is printed on...
Hi, just received today a Blackbox Interface for my Blackbox X4. The instructions mention installing a "TVS Module" in my v2.6 Blackbox, This was...
Peter, you are right. Took ages, much swapping of cables etc to pin down the problem. It was coincidental to using the E Stop button. I eventually...
I hit the emergency button as I had experienced a bit of chip weld on the bit whilst doing some aluminium (using recommended speeds/feeds in an...
Thanks, I will check all the y axis wiring again to make sure nothing has come loose. A quick look when the problem arose (straight after hitting...
The wires are intact (checked that) and the motors run perfectly when they are disconnected from the machine. As soon as there is a load (via...
They are square - until I try to move them using OB Control. They then move erratically jumping around as previously described. Gary