One of two possibilities, depending on the following question: 1) If you turn off the machine, move it away from the switch manually, power up...
Correct yes. Better than no filtering. Ideally at the switch though, not the near end of the cable. That's why Xtension switches runs on 3-core...
Could you share the exact video and timestamp, so we can make sure its corrected
You do want the capacitor and resistor. Resistor 10k between SIG and V+. Capacitor 0.1uF across SIG and GND
Did you work through all the setup documentation during initial setup? Sounds like you possibly skipped over step 7.1 (7.2 relates as well) of the...
I am saying, the Fault indicators for the Y axis stepper driver: See section 1(g) of docs:blackbox-x32:layout [OpenBuilds Documentation] But...
To DC GND or a seperate Earth Spike. Not to the outlet, which is mains earth. Grbl Wiki has a basic schematic
Of course one needs the 24v power to run the motors. But also remember to load a machine profile (CONTROL > Grbl Settings tab > Select a machine...
Y axis fault indicator on when it can't move Y? Timeout is expected (its waiting for Y to hit, but Y can't move. Power cycle clears driver fault...
Option E is preferable: Xtension Limit Switch Kit onboard filtering. No need for shielded wire. None of your schematics has any signal pull up...
2-wire probes - see the Z-probe example in the documentation: docs:blackbox-x32:connect-zprobe [OpenBuilds Documentation] Tool diameter is...
Only Z definately needs to home up-and-away from the stock, XY is fine whereever you want it. OpenBuilds machines by default homes to front-left -...
That sounds like mechanical binding. Support here has been helping you here, but at this point partial teardown to investigate the binding may be...
Does the motor grind, or does is stall, which causes the noise. To figure that out take both motors OFF the machine and test on the bench (good...
Your other thread is here Connecting and using a 2 wire probe (Along with three other duplicate posts)
CONTROL > Grbl Settings tab Post a backup (Backup Settings button on the Grbl Settings tab) if you'd like us to take a look too Also check for...
Not related to the original post (which was all axes without any power). But lets see: Motor going out of alignment can only be one of: 1)...
See the Grbl/grblHAL wiki's for documentation on Firmware parameters As yours is NPN-NC (not just NPN) you may need either one of the following...
Yes but those additional pullup/pulldowns can affect the filters on the X32. We still strongly recommend Xtension Limit Switch Kit