Separate names with a comma.
Some features disabled for guests. Register Today.
When you open the wizard, or when you proceed after entering parameters. If its the latter, you have some value set incorrectly or left empty. If...
OpenBuildsCONTROL > Grbl Settings Tab > Scroll down to $6 Also shown in the Serial Log terminal on connect But do re-read my earlier reply. Use...
Process of elimination - multimeter in continuity between DC GND and Collet, unplugging random stuff till it stops beeping. See earlier linked...
According to docs:machines:comparison [OpenBuilds Documentation] about 200mm - but if in doubt grab the CAD model from the Build page to properly...
Thanks for the suggestion, but not at this time - it is on the roadmap for a future update
Make sure you also have $30=255 (if you want to use M3S255 as max) - grbl default is $30=1000 (which then needs S0-1000)
Those pololu size drivers = disappointment. Get a proper controller: https://docs.openbuilds.com/blackbox
Don't test by running probes just yet, its easier to use the troubleshooting tab to check things out properly Multimeter between the Bosch's...
Any chance you have VFD spindle? Earth to GND short? XYZ Probe Plus with VFDs and other ground-loop inducing components
The port "wlan-debug" is not a USB port. Make sure to select the correct port from the list (in the Flashing tool as well) Mainly though, as the...
Doesn't happen enough to justify such a feature. Something is just randomly up for you. Tune the current (it is an advised step in our docs,...
$6=1 applies to our BlackBox X32 Set $6=0 or 1 - whatever sets it to GREEN when the Magnet doesn't touch the plate and RED when the magnet...
Sitting still works the drivers harder than moving (both coils energised to maintain brake condition, but only one at a time - alternating coils...
A picture of the PSU and in particular all labels would help
RAMPS being a 3D printed board is the wrong choice, so its not likely going to be easy. You'll need to look for a RAMPS compatible fork with...
We don't use machine coordinates for probing. so homing itself is not likely the main issue. But perhaps you forgot to position it over the hole...
Not necessarily, the fault indicator is wired directly to the drivers Fault pin. Over current is one of 4 possible faults. Work through the...
Fault LED is described in docs.openbuilds.com > BlackBox X32 > Current Adjustment
X32 is not arduino based. Very different generation. The older BlackBox 4X was Uno compatible
Compatible yes. Optimal... Not quite. Neither has any of the modern features our Xtension Limits and XYZ Touch Probe plus has. I wouldn't bother...