Separate names with a comma.
Some features disabled for guests. Register Today.
If its from a reputable vendor it should be fine yes. Just watch out for the far east stuff.
If you need exact info so would we. Datasheet / specs of motors for example to see if their resistance, inductance, voltage and current ratings...
We'd rather recommend our Xtension limits. Easier to do parallel than inductives (sometimes needs external circuitry to OR/AND the signal)
Error about missing numeral: You left Pierce Height field Blank in CAM under the Toolpath Options. Enter a number into the field Probe: test...
Sounds like our "TVS Module" Correct, throw it away, it only applies to older Interfaces connecting to BlackBox 4X V2.3-2.6 (2019 to early 2020...
We used to include a TVS module with the Interface years back (no longer do as it was a retrofit for some older BlackBox 4X versions). BlackBox...
You have to use something more advanced like Fusion360
You don't run them as a job (: You use the Probe menu! docs:interface:usage-probe [OpenBuilds Documentation]
Yes with ease. Two two motors on Y is more to prevent racking anyway, doesn't work very hard
Correct. Both Y motors in parallel on Y and the 4th on Y2. Then flash the 4th axis firmware from Wizards and Tools > Firmware flashing tool
Looks good. Just watch out - where you have the BlackBox mounted, it looks like it will be exposed to a lot of cutting dust/chips (even with good...
Don't recall any changes surrounding that part of the code, but drop a ticket into github.com/OpenBuilds/OpenBuilds-CONTROL/issues/new and we can...
Are you migrating from a 4X to and X32? Did you use CONTROL to backup the 4X settings, then again use CONTROL to restore it to new one so CONTROL...
This step: docs:interface:prepare-usb-drive [OpenBuilds Documentation]
As mentioned, not in a way that makes economical sense - tracing out all the damage is several hours, and then replacing components - the labour...
We do not offer a repair service (labour would make than an uneconomical prospect sadly, particular in this example where a large backfed would...
OpenBuildsCONTROL > Grbl Settings > Select a machine from the list (Custom if yours is not listed, and avoid changing advanced defaults like $4,...
Also indicates $1=25 (should be 255 to keep them always on) - but the main mistake is $4 should be 0. Our profiles (including the CUSTOM option...
Try the Web Builder: at http://svn.io-engineering.com:8080/ [ATTACH]
Also more info: Follow onscreen instructions [MEDIA]