Are you using smoke extraction? If so, is the hose earthed (Same as the Dust Extraction section of docs:blackbox:faq-emi [OpenBuilds...
Tool On button on the main toolbar
We recommend the RoutER11 CNC Kit or DeWALT DWP611 Compact Router from our store. If you have to use a VFD based spindle, the 0.8kw/1,5kw 65mm...
See docs:blackbox:faq-emi [OpenBuilds Documentation]
Go to OpenBuilds-CONTROL > Connect > Grbl Settings tab > note the instructions onscreen and scroll down to setup your machine parameters. The...
You cleared the "Cut depth: Start" field - default is 0 (top of material) - but by removing the value entirely you are starting at an undefined...
In what Host application? What machine? Controller and probe are you using? Many different possible alarms, note down the exact code and words...
Good luck! How do you eat an elephant? Tiny bites at a time. Same here, break down your idea into individual bits, and hit Stackoverflow for code...
The PSU can be entering Protection mode from a short circuit somewhere. Test with ONLY the PSU itself, nothing else connected and see if it stays...
Yes, see the Acro's Build Page: OpenBuilds ACRO System > Files and Drawings tab Use Sketchup Make 2017 to open Downloading older versions |...
Unfortunately you uploaded a GCODE file :): Need the OBC file from file > Export workspace of one of your failed setups - as it allows me to view...
Yes, you wire them each as described in docs.openbuilds.com - and control which is active by means of a power switch for each. Grbl has one PWM...
See docs:blackbox:faq-identify-motor-coils [OpenBuilds Documentation] - weird noises is almost always Wiring. Either incorrect pairs, or only 3 of...
Check calibration from Wizards and Tools > Calibration menu
Are you sure you wired it all up right? Sounds like you wired X to Y and vice versa
Have you worked through the FAQ page linked above: EMI is quite easy to address - spacing limits wiring away from EMI sources, using filtered...
Probe type > Custom > Enter values However, they are quite precise. Cutting into your spoilboard could rather be: - Need to recalibrate Z axis:...
The $X message you selected and highlighted? That's not an "$ error" as you referenced earlier, Grbl enters "locked" mode when it...
Use G10: G Codes CONTROL uses it for the Setzero buttons, for example: OpenBuilds-CONTROL/index.html at...
Depends on what bootloader is installed on your Arduino, the genuine namebrand Arduinos have the correct bootloader for the correct model, but the...